ABB AWIN Gateways | HappeningNow.news
Published Date: April 30, 2026

Cybersecurity CISA

ABB AWIN Gateways

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely reboot the device or complete an unauthenticated query to reveal system configuration, including sensitive details. The following versions of ABB AWIN Gateways are affected:…

AI Summary Powered by HappeningNow

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely reboot the device or complete an unauthenticated query to reveal system configuration, including sensitive details. The following versions of ABB AWIN Gateways are affected: ABB AWIN Firmware (2.0-0) installed on ABB AWIN GW100 rev.2 2.0-0  ABB AWIN Firmware (2.0-1) installed on ABB AWIN GW100 rev.2 2.0-1  ABB AWIN Firmware (1.2-0) installed on ABB AWIN GW120 1.2-0  ABB AWIN Firmware (1.2-1) installed on ABB AWIN GW120 1.2-1  CVSS Vendor Equipment Vulnerabilities v3 8.3 ABB ABB AWIN Gateways Authentication Bypass by Capture-replay, Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-13777 An unauthenticated query reveals data. Authentication Bypass due to Improper Session Validation. View CVE Details Affected Products ABB AWIN Gateways Vendor: ABB Product Version: ABB ABB AWIN Firmware (2.0-0) installed on ABB AWIN GW100 rev.2: 2.0-0, ABB ABB AWIN Firmware (2.0-1) installed on ABB AWIN GW100 rev.2: 2.0-1, ABB ABB AWIN Firmware (1.2-0) installed on ABB AWIN GW120: 1.2-0, ABB ABB AWIN Firmware (1.2-1) installed on ABB AWIN GW120: 1.2-1 Product Status: known_affected Remediations Mitigation The following product versions have been fixed: ABB AWIN Firmware 2.1-0 installed on ABB AWIN GW100 rev. 2 (Product ID: 3BNP102988R1) are fixed versions for CVE-2025-13777 ABB AWIN Firmware2.0-0 installed on ABB AWIN GW120 (Product ID 3BNP103003R1) are fixed versions for CVE-2025-13777 Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://psirt.abb.com/csaf/2026/4jno000329.json Relevant CWE: CWE-294 Authentication Bypass by Capture-replay Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H CVE-2025-13778 An unauthenticated query allows an attacker to remotely reboot the device, potentially causing a denial of service. View CVE Details Affected Products ABB AWIN Gateways Vendor: ABB Product Version: ABB ABB AWIN Firmware (2.0-0) installed on ABB AWIN GW100 rev.2: 2.0-0, ABB ABB AWIN Firmware (2.0-1) installed on ABB AWIN GW100 rev.2: 2.0-1, ABB ABB AWIN Firmware (1.2-0) installed on ABB AWIN GW120: 1.2-0, ABB ABB AWIN Firmware (1.2-1) installed on ABB AWIN GW120: 1.2-1 Product Status: known_affected Remediations Mitigation The following product versions have been fixed: ABB AWIN Firmware 2.1-0 installed on ABB AWIN GW100 rev. 2 (Product ID: 3BNP102988R1) are fixed versions for CVE-2025-13778 ABB AWIN Firmware2.0-0 installed on ABB AWIN GW120 (Product ID 3BNP103003R1) are fixed versions for CVE-2025-13778 Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://psirt.abb.com/csaf/2026/4jno000329.json Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-13779 An unauthenticated query reveals the system configuration, including sensitive details. View CVE Details Affected Products ABB AWIN Gateways Vendor: ABB Product Version: ABB ABB AWIN Firmware (2.0-0) installed on ABB AWIN GW100 rev.2: 2.0-0, ABB ABB AWIN Firmware (2.0-1) installed on ABB AWIN GW100 rev.2: 2.0-1, ABB ABB AWIN Firmware (1.2-0) installed on ABB AWIN GW120: 1.2-0, ABB ABB AWIN Firmware (1.2-1) installed on ABB AWIN GW120: 1.2-1 Product Status: known_affected Remediations Mitigation The following product versions have been fixed: ABB AWIN Firmware 2.1-0 installed on ABB AWIN GW100 rev. 2 (Product ID: 3BNP102988R1) are fixed versions for CVE-2025-13779 ABB AWIN Firmware2.0-0 installed on ABB AWIN GW120 (Product ID 3BNP103003R1) are fixed versions for CVE-2025-13779 Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch Mitigation For more information see the associated ABB PSIRT security advisory 4JNO000329 ABB CYBERSECURITY ADVISORY - PDF Version https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch, ABB CYBERSECURITY ADVISORY - CSAF Version https://psirt.abb.com/csaf/2026/4jno000329.json. https://psirt.abb.com/csaf/2026/4jno000329.json Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H Acknowledgments Fred Alvarez reported these vulnerabilities to ABB Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-04-30 Date Revision Summary 2026-04-30 1 Initial Republication of ABB 4JNO000329 Legal Notice and Terms of Use

AI summaries can be wrong sometimes—always verify important details using the source link below.

Read full article at cisa.gov
Category Cybersecurity
Outlet CISA
Source cisa.gov